ZF Repair Manual: ZF25A, ZF25, ZF45A, ZF45-1
<< Previous of 78 Next >>4.7 FLUID FILTER
4.7.1 Mounting the fluid filter
ZF25A - ZF25 OLD VERSION
.
Place filter element (item 1 Fig. 7-1a) and seal (item
2 Fig. 7-1a) onto the transmission.
.
Place filter cover (item 3 Fig. 7-1a) and lock it to the
transmission by screwing in bolts (item 4 Fig. 7-1a).
Tightening torque: 18 Nm (14 ft.lb.).
ZF25A - ZF25 - ZF45A - ZF45-1
.
Wet O-rings (item 1 and 2, Fig. 7-1b) with some
ATF fluid and mount them.
.
Install filter element (item 3, Fig. 7-1b) into the
transmission.
.
Lock cover (item 4 Fig. 7-1b) to the transmission
using an allen wrench. Tightening torque: min 5
Nm - max 8 Nm. (min 4 ft.lb. - max 6 ft.lb.)
4.8 OUTPUT FLANGE
Provide spline (X) of output shaft with a thin coat of Loc-
tite 245 and sealing lip (Z) of shaft seal with a thin coat
of ATF fluid. (Fig. 8-1a and b)
Fit output flange (item 1, Fig. 8-1 a and b).
Provide 0-ring (item 2, Fig. 8-1 a and b) with ATF fluid
and insert into output flange.
ZF25A - ZF25 - ZF45A
Tighten output flange down on output shaft with nut
ring (item 3, Fig. 8-1a).
Tightening torque; 120 Nm (89 ft.lb.) use socket span-
ner tool p/n 500446
ZF45-1
Tight output flange down on output shaft with bolt (item
3, Fig 8-1b) and washer (4).
Tightening torque: 100Nm (74 ft.lb.)
27
Repair Manual and Spare Parts List
Section 4
1
2
3
4
FIG. 7 - 1a
4
2
1
3
FIG. 7 - 1b
FIG. 8 - 1a
1
2
4
3
X
Z
FIG. 8 - 1b